Passive Solar Water Heater Specifications
|
|
|
|
Specifications:
Metric/US
|
PT30
|
PT40
|
PT50
|
|
Volumetric Capacity: l / gal
|
116.7 / 30.84
|
156.7 / 41.40
|
194.5 / 51.44
|
|
Gross Area: m2 / ft2
|
2.23 / 23.98
|
2.98 / 32.10
|
2.98 / 32.10
|
|
Transparent Frontal Area: m2 / ft2
|
76.2 / 168
|
99.7 / 220
|
106.5 / 235
|
|
Dry Weight: kg / lbs
|
76.2 / 168
|
99.7 / 220
|
106.5 / 235
|
|
Wet Weight: kg / lbs
|
192.7 / 425
|
255.2 / 563
|
301.1 / 664
|
|
Flow Pattern:
|
Series
|
Series
|
Series
|
|
Test Pressure: KPa / psi
|
2068 / 300
|
2068 / 300
|
2068 / 300
|
|
Design Pressure: KPa / psi
|
1034 / 150
|
1034 / 150
|
1034 / 150
|
|
Maximum Design Temp: C / F
|
176 / 350
|
176 / 350
|
176 / 350
|
|
Normal Operating Temp: C / F
|
4-93 / 40-200
|
4-93 / 40-200
|
4-93 / 40-200
|
Dimensions
Metric/US |
PT30 |
PT40 |
PT50 |
|
A cm / in |
247.5 / 97.44 |
247.5 / 97.44
|
247.5 / 97.44 |
|
B cm / in |
90.0 / 35.44 |
90.0 / 35.44 |
90.0 / 35.44 |
|
C cm / in |
241.9 / 95.25 |
241.9 / 95.25 |
241.9 / 95.25 |
|
D cm / in |
84.1 / 33.125 |
114.6 / 45.125 |
114.6 /45.125 |
|
E cm / in |
250.0 / 98.44 |
250.0 / 98.44 |
250.0 / 98.44 |
|
F cm / in |
19.7 / 7.75 |
19.7 / 7.75 |
19.7 / 7.75 |
|
G cm / in |
247.2 / 97.313 |
247.2 / 97.313 |
247.2 / 97.313 |
|
H cm / in |
6.9 / 2.75 |
6.9 / 2.75 |
6.9 / 2.75 |
|
I cm / in |
2.5 / 1.0 |
2.5 / 1.0 |
2.5 / 1.0 |
|
J cm / in |
8.9 / 3.5 |
8.9 / 3.5 |
8.9 / 3.5 |
|
K cm / in |
7.6 / 3.0 |
7.6 / 3.0 |
7.6 / 3.0 |
|
L cm / in |
13.9 / 5.5 |
13.9 / 5.5 |
13.9 / 5.5 |
|
M cm / in |
70.5 / 27.75 |
100.9 / 39.75 |
100.9 / 39.75 |
|
N cm / in |
89.7 / 35.3125 |
120.2 / 47.313 |
120.2 / 47.313 |
|
P cm / in |
9.2 / 3.625 |
9.2 / 3.625 |
9.2 / 3.625 |
|
Q cm / in |
15.6 / 6.125 |
15.6 / 6.125 |
15.6 / 6.125 |
|
R cm / in |
6.2 / 2.44 |
6.2 / 2.44 |
6.2 / 2.44 |
System Performance Ratings:
QNet: (2000 BTU/FT2/Day) = 31,870 BTU/Day
QNet: (1500 BTU/FT2/Day) = 24,208 BTU/Day
QNet: (1000 BTU/FT2/Day) = 16,540 BTU/Day
Performance Certified by Florida Solar Energy Center
|
Model PT20
|
| Gross Length |
6.97 feet |
| Gross Width |
1.80 feet |
| Gross Depth |
.65 feet |
| Gross Area |
12.56 square feet |
| Transparent Frontal Area |
10.77 square feet |
| Volumetric Capacity |
17.9 gallons |
| Weight (empty) |
92.0 pounds |
| Recommended Flow Rate |
On demand only |
| Test Pressure |
160 psig |
| Number of Cover Plates |
Two |
| Flow Pattern |
Series - Forced circulation |
| Number of Flow Tubes |
Four |
Net Energy Delivered (QNet): 3.4 kWh - 11,600 Btu
Heat Loss Coefficiency (L): 3.9 W/ºC - 7.5 Btu/hrºF
System Description and Thermal Performance (PDF):
Summary Information Sheet PT-20-CN
Summary Information Sheet PT-30-CN
Summary Information Sheet PT-40-CN
Summary Information Sheet PT-50-CN
|
|
|
|
|
|
|
|
|